1.
Pharmacy (Basel) ; 11(2)2023 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-36961026

RESUMEN

For patients with cardiac implantable electronic devices (CIEDs), arrythmias such as atrial fibrillation (AF) can be detected and actions taken to rapidly assess and initiate treatment where appropriate. Actions include timely initiation of anticoagulation, review of blood pressure, and optimization of cholesterol/lipids to prevent unfavorable outcomes, such as stroke and other cardiovascular complications. Delays to initiating anticoagulation can have devastating consequences. We sought to implement a virtual clinic, where a pharmacist reviews patient referrals from a CIED clinic after detecting AF from the CIED. Anticoagulation choice is determined by patient-specific factors, and a shared patient-provider decision to start oral anticoagulation is made. In addition, blood pressure readings and medications are assessed with lipid-lowering therapies for optimization. A total of 315 patients have been admitted through this clinic and anticoagulated over a two-year span; in addition, 322 successful interventions were made for optimization of cardiac therapy. Rapid initiation of anticoagulation within five days of referral was likely to have reduced unfavorable outcomes, such as stroke and other cardiovascular optimizations, leading to improved patient outcomes.